A Case Study on Eilersen Beam Load Cells:

Bạn mong muốn tìm kiếm cân công nghiệp chính hãng chất lượng cao hay cân điện tử giá rẻ, hãy cho Hoa sen vàng biết và nhận sự tư vấn nhiệt tình-chu đáo, sản phẩm đều có giá trị và đặc tính riêng của chúng … hãy Gọi ngay : 028 3511 7799 (kinh doanh) hoặc truy cập website: https://hoasenvang.com.vn/shops/ (sản phẩm)

Eilersen continuously partners with industry leaders to qualify our equipment and concepts in real-world conditions and simulated process environments. In this study, we partnered with a Belgian mechanical and electrotechnical engineering firm to test the performance of capacitive load cells on mobile totes and mixers for biopharma manufacturing.

The biopharma industry has increasingly adopted single-use equipment and mobile totes in recent years. This is due to the flexibility it provides, enabling manufacturers to make changes in manufacturing layout faster than before. Other benefits are also valued, as single-use equipment leads to a lower risk of contamination and reduced time and costs associated with cleaning and validation.

The use of mobile totes can however present a challenge when it comes to other aspects. As load cells using strain gage technology are sensitive to the sideloads they encounter in such an application, accurately measuring the product's weight in the tote or mixer can be a problem. Movements and uneven surfaces can result in strain gage load cells being impacted, losing calibration, and thus leading to inaccurate measurements.

The Limitations of Strain Gage Load Cells:

A large international biopharma manufacturer encountered several challenges when pushing around their mobile totes equipped with strain gage load cells. During daily activities, mobile totes are frequently pushed around carrying bags of liquids. To prevent the load cells from being overloaded, many strain gage load cells are installed with some variety of mechanical protection such as brackets or stay rods. During high sideloads the stay rods and brackets protect the load cell. However, after impact, the tension between the load cells and stay rods affects the weight reading and accuracy, causing a need for recalibration of the entire weighing system. Such issues are well documented and caused by simple movements such as technicians turning the tote around corners, pushing, or pulling the tote. Key limitations relating to the use of strain gage load cells include:

  • Strain gage load cells can be overloaded by the impact occurring when rolling over bumps and uneven surfaces when moved between locations.
  • Strain gage load cells can be overloaded when being pushed around the facility using an electrical mover.
  • Strain gage load cells can be overloaded by the sloshing of liquids in the mobile tote during transportation.
  • The mechanical elements protecting the strain gage load cells introduce tension that influences weight reading and accuracy.

If the technicians suspect that the load cells on a mobile tote have been overloaded, a recalibration of the weighing system is required. This process will take the tote out of production for several hours and can cost thousands of dollars, due to the use of expensive single-use bags, a large volume of purified water, and time spent on documentation.

To overcome these challenges, the biopharma manufacturer installed a mechanical “transport lock” by each strain gage load cell to protect the load cell from the impact of bumps and sloshing liquids whenever the tote was moved around the facility. For this system to work properly, the daily operators would have to manually engage and disengage the brackets before and after moving the tote. In practice this action was frequently forgotten, causing deviations, and requiring recalibration of the weighing systems. To solve this important issue, the biopharma manufacturer approached the Belgian mechanical and electrotechnical engineering firm, specializing in the design and production of parts for pharmaceutical companies.

Assessment of Capacitive Load Cells:

Being familiar with the capacitive technology of Eilersen load cells, the engineering firm knew that capacitive load cells do not require transport locks, stay rods, or brackets for overload protection due to the capacitive weighing technology. While strain gage load cells measure the change of resistance, the capacitive technology instead measures the change of distance between the load cell body and an internal ceramic sensor. This patented contactless measurement principle makes the capacitive weighing technology resistant to sideload and able to handle up to 1,000% overload.

A test system was required to assess the performance of the capacitive technology when subjected to the impacts of daily operations in the biopharma industry. Therefore, a mobile tote was retrofitted using the following products from Eilersen:

  • 3 pcs BL 150kg beam-type load cells
  • 1 pc 5024G Digital LCD Weighing Indicator

Tests were conducted after retrofitting the tote with Eilersen load cells to measure the influence of movements on both smooth and uneven surfaces while transporting a mobile tote at full capacity.

Test on smooth and even surface:

For the first test, an empty tote was calibrated and validated. A 200L single use bag was installed and the tote was zeroed. The tote was then filled with water to resemble the approximate full working weight of the tote. Before starting the test, the load indication was noted. During the test, the tote was pushed through a room, stopped, and pushed around a corner and the results were measured with a resolution of 10 grams. The experience of the biopharma manufacturer was that such movements would often result in a measured difference exceeding 5kg when using strain gauge load cells if the transport locks were not engaged.

Results:

After being pushed around at full capacity without lockout kits, the Eilersen weighing indicator displayed a difference of only 0.020% full scale, which is better than the rated load cell accuracy of 0.025%. The results were well within the MPE (Maximum Permissible Error) requirements of the biopharma manufacturer.

Test on Uneven Surfaces:

An aluminum plate and a wooden plate were used as a simulation of obstacles commonly encountered by a mobile tote. The plates were placed on the floor in front of the mobile tote causing an impact force when rolled over. Two tests were conducted – one in which two side wheels encountered the aluminum plate and another in which all four wheels encountered the wooden plate. The biopharma manufacturer had previously experienced a significant variation when strain gage load cells were subjected to similar impacts caused by a full tote rolled over such plates.

Results:

After rolling over the aluminum and wooden plates of 3 and 4 mm, the weighing indicator cells displayed a variation of between 0.010% and 0.020% of full-scale after impact without utilizing lockouts or any protective devices. These results were within the MPE (Maximum Permissible Error) requirements of the biopharma manufacturer.

Conclusion:

The replacement of strain gage load cells with Eilersen capacitive beam-type load cells resulted in a weighing system being able to sustain sideloads due to movements and impacts commonly occurring during daily operation. Following tests conducted at full tote capacity, the weighing system based on Eilersen capacitive load cells exhibited only minor differences that were well within their rated accuracy.

Following these results, the biopharma manufacturer decided to replace their existing strain gage-based weighing systems with Eilersen digital beam load cells for all mobile tanks in their manufacturing process.

Over time, replacing strain gage load cells will lead to a decrease in unforeseen instances of inaccurate weighing data and a reduction in downtime caused by the need for recalibration. After changing load cell technology, the biopharma manufacturer has gained enhanced flexibility, eliminated expenses associated with overload-protection brackets and cleaning, and alleviated concerns regarding deviations in their weighing systems.

    Summary:

    • Strain gage load cells need “overload-protection brackets” and “transport locks” to protect from sideloads and impacts during daily use.
    • Capacitive technology can handle up to 1,000% overload due to the contactless measurement principle.
    • Capacitive load cells allow reading of individual load cell values and replacement of load cell cables on-site without the need for recalibration.
    • The movement tests on uneven surfaces showed satisfying results with a deviationthat were will within the MPE of the plant.

    * There you go the latest news at Blog.hoasenvang.com.vn, weighing news on precision Measuring Equipment and weighing control devices, Using Eilersen Capacitive Load Cells to increase uptime for Mobile Totes in Biopharma production all free news and non-profit, High accuracy floor type counting scale with large platform for heavier items. Weight & count preset range (HI/OK/LO) and alarm beep. Heavy-duty pallet weighing platform scale. Above ground or In-floor installation available. Powder coated & anti-skid suface. Load cell wire protection (flexi-cable). News for free, Yes.. All purpose serving you is my pleasure.

    [High quality Ads] Có thể bạn đã biết cân kỹ thuật điện tử phân phối: Công ty TNHH Thiết bị đo lường Hoa sen vàng giới thiệu Cân điện tử chính xác là thiết bị đo có thiết kế nhỏ gọn, dễ sử dụng và nhanh chóng ổn định cân hoa sen vàng điện tử có mức tải trọng lớn và đa dạng (1 kg – 100 tấn) sai số nhỏ hơn so với các loại cân thông thường khác (cân cơ học, cân đồng hồ), cân điện tử hoa sen vàng có nhiều ứng dụng trong đời sống và kinh doanh, có nhiều đơn vị cân như gram, kilogram, lb, ct, … Cân công nghiệp điện tử đầu cân điện tử tốt nhất một trải nghiệm thú vị với vô số các sản phẩm cân và phụ kiện – Golden Lotus Measuring Equipment, weighing scales news, electronic scale news, load cell news, retail scale news, industrial scale news, … Using Eilersen Capacitive Load Cells to increase uptime for Mobile Totes in Biopharma production International Electronic Weighing for Feature Thanks to Weighing_review web site for World all-inclusive Weighing Scales News. All noesis on the Blog is meted out and is not accountable for the noesis meted out for any advertizing intention or truth accounting data. Please do not mark, all changes are triple-crown to the producer without prior find.


    * Thiết bị hiển thị đo lường

    Can dien tu Dini Argeo hoa sen vang
    Hello there !

    Show Comments

    No Responses Yet

    Leave a Reply

    Time limit is exhausted. Please reload CAPTCHA.